200-600kVA PF=0.9 (3:3) high frequency online double-conversion UPS with DSP control
Delivery term:The date of payment from buyers deliver within days- Price:
Negotiable
- minimum:
- Total supply:
- Delivery term:
The date of payment from buyers deliver within days
- seat:
Beijing
- Validity to:
Long-term effective
- Last update:
2017-10-27 15:40
- Browse the number:
107
Company Profile
- American Wise Power Technologies, Inc By certification [File Integrity]
-
Contact:
eastsolar(Ms.)
- Telephone:
-
Area:
Beijing
-
Address:
1418 Lexington Street, Tustin, California, United States
- Website: http://eastsolar.netatomi.com/
Product details
Model Number: 200k ~ 600kVA (3:3)
Brand Name: AWP
Key Specifications/Special Features:
Ideal applications:Data centers, computer room, ISP, telecommunications, finance, security, taxation, bankingEA990 series 200-600kVA is three-phase input and three-phase output uninterruptible power supply system with high frequency on-line double-conversion technology controlled by DSP (digital signal processor) microprocessorAdopts a highly intelligent modular design to achieve utmost compact layout and improve reliability of the systemMeets the protection demands of critical loads in data centers or other important applications with high electrical performance and hardware/software protectionsFeatures:DSP digital control technologyPure sine wave double conversion, with strong load capacity
Modular design, high reliability and easy maintenance
Dual input power distribution for higher usability
Input power factor > 0.99, THDi < 3%, environment-friendly and high-efficiency and energy-saving
Keep high efficiency operation at low load rate: 96 at 40% rated load and 95 at 20% rated load
High power density, 500kVA system only 1.02m2 footprint
High efficiency operating in on-line mode up to 96%, in eco-friendly mode up to 99%
Wide input voltage range, 50/60Hz frequency anti-sense, adapts to all kind of grid
Supports two modes of frequency conversion: 50Hz input/60Hz output and 60Hz/input 50Hz output
Output power factor 0.9, load capability improved 12.5% more than traditional products
Advanced parallel expansion technology, support 4 units in parallel
Share battery packing in parallel operation, saving user’s battery cost
Flexible charger parameter and battery configuration setting, battery number 30 to 46 pieces selectable
Intelligent battery management (intelligent charge/discharge management and float charging voltage temperature compensation), extending battery lifespan
Supports battery cold start and utility self boot
Self-aging function, easy debugging and test on site
Complete hardware and software protection function, robust self-diagnostic function and abundant event log for check
7-inch LCD touchscreen, friendly human-machine interface
Monitoring unit with built-in SNMP, supports RS485 and dry contacts
MODEL | MOD 200 | MOD 300 | MOD 400 | MOD 500 | MOD 600 |
Rated max capacity | 200kVA | 300kVA | 400kVA | 500kVA | 600kVA |
Numbers of power modules | 4 | 6 | 8 | 10 | 12 |
Rated capacity of power module | 50kVA | ||||
Input | |||||
Input wiring | 3Ph + N + PE | ||||
Rated voltage | 380/400/415V AC | ||||
Voltage range | 138-485V AC (305-485V AC without power downgrading, 138-305V AC with linear downgrading 40%) | ||||
Input frequency | 40-70Hz | ||||
Power factor | ≥ 0.99 | ||||
Harmonic current distortion | < 3% THDi | ||||
Batteries | |||||
Type | VRLA/AGM maintenance-free lead based | ||||
Battery voltage | ± 240V DC (± 180/192/204/216/228/252/264/276V DC selectable) | ||||
Number of battery | 40 pieces (30/32/34/36/38/42/44/46 pieces selectable) | ||||
Max charging current | 10A x quantity of configured power modules (settable) | ||||
Output | |||||
Output wiring | 3Ph + N + PE | ||||
Rated voltage | 380/400/415V AC | ||||
Voltage accuracy | ± 1% | ||||
Frequency | Mains mode: synchronized with utility Battery mode: 50/60Hz ± 0.25% |
||||
Power factor | 0.9 | ||||
Voltage distortion | ≤ 1% with liner load/ ≤ 3% with non-linear load | ||||
Dynamic variation | ± 5% | ||||
Transient recovery time | < 20 minutes | ||||
Crest factor | 3:1 | ||||
Inverter overload capacity | 105-110% for 60 minutes, 110-125% for 10 minutes 125-150% for 1 minute, > 150% for 200 minutes |
||||
Bypass overload capacity | Load ≤ 135% for long term running: 135% < load <1000% for 100 minutes | ||||
System | |||||
Efficiency | 96 % | ||||
Max number of parallel | 4 units | ||||
Transfer time | 0 minute | ||||
Protections | Short-circuit, overload, over-temperature, overvoltage, under voltage, battery low voltage, output low/over voltage and fans failure | ||||
Communications | RS485, dry contacts, FE port (SNMP) | ||||
Display | 7 inches LCD touchscreen | ||||
Others | |||||
Operating temperature | 0 to 40°C | ||||
Storage temperature | - 40 to 70°C | ||||
Humidity | 0-95% (non-condensing) | ||||
Altitude | 0-4000m Above 1000m, derating 1% for each additional 100m |
||||
IP rating | IP 20 | ||||
Noise level at 1 m | <65dB | <68dB | |||
Cabinet dimensions | (W) 600 x (D) 850 x (H) 2000mm | (W) 1200 x (D) 850 x (H) 2000mm | (W) 1400 x (D) 850 x (H) 2000mm | ||
UPS module dimensions | (W) 442 x (D) 620 x (H) 130mm | ||||
Cabinet weight | 213kg | 426kg | 426kg | 448kg | 568kg |
UPS module weight | 32kg |
Shipping Information:
- FOB Port: Shenzhen
- Lead Time: 15 - 30 days
Main Export Markets:
- Asia
- Australasia
- Central/South America
- Eastern Europe
- Mid East/Africa
- North America
- Western Europe
New Products
-
Laundry Pool Mould
price: Negotiable
-
Selective Pallet Crossbeam Shelves
price: Negotiable
-
Boldenone CAS 846-48-0
price: Negotiable
-
High Strength Stainless Steel Slaughter Chain
price: Negotiable
-
700ml Shaker Bottle
price: Negotiable
-
Motorcycle Rear Paddock Stands
price: Negotiable